BMA Series Generating Set

 

Item No

Genset Model
Open Type

Genset Model
Sound Proof

Power Out Put
400V/50HZ/1500RPM/3P/0.8Y

Beinei
Engine
Model

Mecc Alte
Alternator
Model

Prime 40

Standby 27

1

BMA35OP

BMA35SP

24.8kW

31.0kVA

27.8kW

34.7kVA

F4L912

ECO32-1S/4

2

BMA39OP

BMA39SP

28.0kW

35.0kVA

31.0kW

38.8kVA

F4L912T

ECO32-2S/4

3

BMA45OP

BMA45SP

32.0kW

40.0kVA

35.7kW

44.6kVA

F4L912T

ECO32-3S/4

4

BMA56OP

BMA56SP

40.0kW

50.0kVA

44.8kW

56.0kVA

F6L912

ECO32-1L/4

5

BMA67OP

BMA67SP

48.0kW

60.0kVA

53.2kW

66.5kVA

F6L912T

ECO32-2L/4

6

BMA78OP

BMA78SP

56.0kW

70.0kVA

62.2kW

77.7kVA

BF6L913

ECO32-3L/4

7

BMA95OP

BMA95SP

68.0kW

85.0kVA

75.8kW

94.7kVA

BF6L913

ECP34-1S/4

8

BMA110OP

BMA110SP

80.0kW

100.0kVA

88.0kW

110.0kVA

BF6L913

ECP34-2S/4

9

BMA116OP

BMA116SP

84.0kW

105.0kVA

92.8kW

116.0kVA

BF6L913C

ECP34-2S/4

10

BMA142OP

BMA142SP

104.0kW

130.0kVA

113.6kW

142.0kVA

BF6L913C

ECP34-1L/4

 

 

Item No

Genset Model
Open Type

Genset Model
Sound Proof

Power Out Put
480V/60HZ/1800RPM/3P/0.8 Y

Beinei
Engine
Model

Mecc Alte
Alternator
Model

Prime 40

Standby 27

1

BMA40OP

BMA40SP

29.8kW

37.2kVA

32.0kW

40.0kVA

F4L912

ECO32-1S/4

2

BMA47OP

BMA47SP

33.6kW

42.0kVA

37.6kW

47.0kVA

F4L912T

ECO32-2S/4

3

BMA54OP

BMA54SP

38.4kW

48.0kVA

43.2kW

54.0kVA

F4L912T

ECO32-3S/4

4

BMA68OP

BMA68SP

48.0kW

60.0kVA

54.4kW

68.0kVA

F6L912

ECO32-1L/4

5

BMA80OP

BMA80SP

57.5kW

72.0kVA

64.0kW

80.0kVA

F6L912T

ECO32-2L/4

6

BMA90OP

BMA90SP

65.4kW

81.7kVA

72.0kW

90.0kVA

F6L912T

ECO32-3L/4

7

BMA114OP

BMA114SP

81.6kW

102.0kVA

91.2kW

114.0kVA

BF6L913

ECP34-1S/4

8

BMA130OP

BMA130SP

96.0kW

120.0kVA

104.0kW

130.0kVA

BF6L913

ECP34-2S/4

9

BMA140OP

BMA140SP

101.0kW

126.0kVA

112.0kW

140.0kVA

BF6L913C

ECP34-2S/4

10

BMA170OP

BMA170SP

125.0kW

156.0kVA

136.0kW

170.0kVA

BF6L913C

ECP34-1L/4

 

 

Item No

Genset Model
Open Type

Genset Model
Sound Proof

Power Out Put
220V/60HZ/1800RPM/3P/0.8YY

Beinei
Engine
Model

Mecc Alte
Alternator
Model

Prime 40

Standby 27

1

BMA40OP

BMA40SP

30.0kW

37.2kVA

32.0kW

40.0kVA

F4L912

ECO32-1S/4

2

BMA47OP

BMA47SP

33.6kW

42.0kVA

37.6kW

47.0kVA

F4L912T

ECO32-2S/4

3

BMA54OP

BMA54SP

38.4kW

48.0kVA

43.2kW

54.0kVA

F4L912T

ECO32-3S/4

4

BMA68OP

BMA68SP

48.0kW

60.0kVA

54.4kW

68.0kVA

F6L912

ECO32-1L/4

5

BMA76OP

BMA76SP

54.4kW

68.0kVA

60.5kW

75.6kVA

F6L912T

ECO32-2L/4

6

BMA90OP

BMA90SP

64.0kW

80.0kVA

71.6kW

89.5kVA

F6L912T

ECO32-3L/4

7

BMA114OP

BMA114SP

81.6kW

102.0kVA

91.2kW

114.0kVA

BF6L913

ECP34-1S/4

8

BMA130OP

BMA130SP

96.0kW

120.0kVA

104.0kW

130.0kVA

BF6L913

ECP34-2S/4

9

BMA140OP

BMA140SP

101.0kW

126.0kVA

112.0kW

140.0kVA

BF6L913C

ECP34-2S/4

10

BMA158OP

BMA158SP

116.0kW

145.0kVA

126.4kW

158.0kVA

BF6L913C

ECP34-1L/4

11

BMA170OP

BMA170SP

125.0kW

156.0kVA

136.0kW

170.0kVA

BF6L913C

ECP34-2L/4

 

Standard Scope of Supply:
Open Type Genset:
1. BEINEI Air Cooled G-Drive Engine;
2. M
ecc Alte Brushless AC Alternator;
3. Mild Steel Skid Base with set mount anti-vibration isolators and 6-8 hours Base Fuel Tank;
4. Set Mount Bernini Be24 Control Panel with ComAp AMF25 and Deepsea 5110 as option;
5. Standard 3P Fixed Type MCCB;
6. Flexible Bellow and Industrial Type Silencer;
7. Lead Acid Battery;
8. O&M Manual;
Sound Proof Genset:
1. BEINEI Air Cooled G-Drive Engine;
2. M
ecc Alte Brushless AC Alternator;
3. Mild Steel Skid Base with set mount anti-vibration isolators and 6-8 hours Base Fuel Tank;
4. Sound Proof Canopy Enclosure,Noise Level ≤75dBA@7M;
5. Set Mount Bernini Be24 Control Panel with ComAp AMF25 and Deepsea 5110 as option;
6. Standard 3P Fixed Type MCCB;
7. Flexible Bellow and Residential Type Silencer;
8. Lead Acid Battery;
9. O&M Manual;
RatingDefinitions
Prime Power      
These ratings are applicable for supplying continuous electrical power ( at variable load ) in lieu of
commercially purchased power. There is no limitation to the annual hours of operation and this
model can supply above specified overload standby power for 1 hour in 12 hour.
Standby Power      
These ratings are applicable for supplying continuous electrical power ( at variable load ) in event
of a utility power failure. No overload is permitted on these ratings. The alternator on this model
is peak continuous rated and don't allowed continuous.
Note: 
Standard reference conditions 27℃ Air Inlet Temp, 152.4m (500ft) A.S.L.60% relative humidity. 
All engine performance data based on the above mentioned maximum continuous ratings. 
Fuel consumption data at full load with diesel fuel with specific gravity.

Network | Services | Join us | Contact us

Copyright © 1996-2010 天津泰美特动力科技有限公司 All Rights Reserved.

津ICP备12008239号